Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Braz. J. Pharm. Sci. (Online) ; 58: e18630, 2022. tab, graf
Article in English | LILACS | ID: biblio-1364418

ABSTRACT

Abstract The objective of the present investigation was to design, optimize and characterize the gastro retentive floating levofloxacin tablets and perform in-vivo evaluation using radiographic imaging. The floating tablets were prepared by using polymers i.e hydroxy propyl methyl cellulose (HPMC-K4M) and carbopol-940 individually and in combination by nonaquous granulation method. All the Formulations were evaluated for swelling index (S.I), floating behavior and in-vitro drug release kinetics. The compatibility study of levofloxacin with other polymers was investigated by FTIR, DSC, TGA and XRD. Results from FTIR and DSC revealed no chemical interaction amongst the formulation components. The optimized formulation (F11) showed floating lag time (FLT), total floating time (TFT) swelling index (S.I) of 60 sec, >16h and approximately 75 %, respectively. Moreover, F11 showed zero order levofloxacin release in simulated gastric fluid over the period of 6 h. X-ray studies showed that total buoyancy time was able to delay the gastric emptying of levofloxacin floating tablets in rabbits for more than 4 hours. In conclusion the optimized formulation (F11) can be used for the sustained delivery of levofloxacin for the treatment of peptic ulcer.


Subject(s)
Drug Liberation , Peptic Ulcer/classification , Tablets/pharmacology , X-Rays/adverse effects , In Vitro Techniques/instrumentation , Spectroscopy, Fourier Transform Infrared , Drug Compounding/instrumentation , Process Optimization/analysis , Levofloxacin/analysis , Gastric Emptying/drug effects
2.
Braz. j. pharm. sci ; 51(1): 203-211, Jan-Mar/2015. tab, graf
Article in English | LILACS | ID: lil-751358

ABSTRACT

Average bioequivalence of two 500 mg levofloxacin formulations available in Brazil, Tavanic(c) (Sanofi-Aventis Farmacêutica Ltda, Brazil, reference product) and Levaquin(c) (Janssen-Cilag Farmacêutica Ltda, Brazil, test product) was evaluated by means of a randomized, open-label, 2-way crossover study performed in 26 healthy Brazilian volunteers under fasting conditions. A single dose of 500 mg levofloxacin tablets was orally administered, and blood samples were collected over a period of 48 hours. Levofloxacin plasmatic concentrations were determined using a validated HPLC method. Pharmacokinetic parameters Cmax, Tmax, Kel, T1/2el, AUC0-t and AUC0-inf were calculated using noncompartmental analysis. Bioequivalence was determined by calculating 90% confidence intervals (90% CI) for the ratio of Cmax, AUC0-t and AUC0-inf values for test and reference products, using logarithmic transformed data. Tolerability was assessed by monitoring vital signs and laboratory analysis results, by subject interviews and by spontaneous report of adverse events. 90% CIs for Cmax, AUC0-t and AUC0-inf were 92.1% - 108.2%, 90.7% - 98.0%, and 94.8% - 100.0%, respectively. Observed adverse events were nausea and headache. It was concluded that Tavanic(c) and Levaquin(c) are bioequivalent, since 90% CIs are within the 80% - 125% interval proposed by regulatory agencies.


A bioequivalência média de duas formulações de levofloxacino disponíveis no Brasil, Tavanic(c) (Sanofi-Aventis Farmacêutica Ltda, Brasil, produto referência) e Levaquin(c) (Janssen-Cilag Farmacêutica Ltda, Brasil, produto teste) foi determinada por meio da realização de ensaio aleatório, aberto, cruzado, com dois períodos e duas sequências, em 26 voluntários sadios em condições de jejum. Amostras de sangue dos voluntários foram obtidas ao longo de um período de 48 horas após administração de dose única de 500 mg de levofloxacino. As concentrações plasmáticas do fármaco foram determinadas por método cromatográfico validado. Os parâmetros farmacocinéticos Cmax, Tmax, Kel, T1/2el, AUC0-t e AUC0-inf foram calculados por análise não compartimental. A bioequivalência foi determinada pelo cálculo de intervalos de confiança 90% (IC 90%) para as razões entre os valores de Cmax, AUC0-t e AUC0-inf obtidos para os produtos teste e referência, usando dados transformados logaritmicamente. A tolerabilidade foi avaliada pelo acompanhamento dos sinais vitais e resultados de exames laboratoriais, por consultas e por relato espontâneo dos voluntários. ICs 90% para Cmax, AUC0-t e AUC0-inf foram 92.1% - 108.2%, 90.7% - 98.0%, e 94.8% - 100.0%, respectivamente. Os eventos adversos observados foram náusea e cefaleia. Concluiu-se que os produtos Tavanic(c) e Levaquin(c) são bioequivalentes, uma vez que os ICs 90% estão dentro da faixa de 80%-125% proposta pelas agências reguladoras.


Subject(s)
Humans , Volunteers/classification , Therapeutic Equivalency , Random Allocation , Single Dose/drug effects , Levofloxacin/analysis , Pharmacokinetics , Chromatography, Liquid/methods
SELECTION OF CITATIONS
SEARCH DETAIL